ERROR!

This web site requires Java Script.
You must enable Java Script on
your browser to navigate this site.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Isolated/Stackable DAQ Module HMI SCADA Software
 

Isolated Stackable DAQ
Modules with Free Software

We offer a full line of low-cost Data Acquisition and Control modules which can be daisy chained together and connected to a single communications port of a PC or Laptop. Because these modules are stackable, allows the user to select any combination of features needed for their application, and to expand with additional features when necessary. Our Data Collection Software as pictured above is specifically designed to communicate with these DAQ modules and can be set up very quickly and easily by the novice using little or no programming skills. For more advanced programs with special requirements, our engineers can put together a custom software application for you. This can include the mapping of all of the data points to individual cells in your Excel Spreadsheet which will update automatically.

 

Pulse Measurement Module

Pulse Timer Card Pulse Counter/Timer Card WTPCT-M
Measures the precise duration of a high or low going pulse applied to its input using 1µS resolution. The pulse length can be in the range of 10µS to 3.355443 Seconds. read more...

 

Stackable Capability

Stackable refers to the ability to connect multiple units together and share a single communications port of a host PC, laptop, or Single Board Computer (SBC). The communications bus uses a stratagem based on the Carrier Sense Multiple Access (CSMA/CD) protocol. Carrier Sense (CS) is the monitoring of the data bus for a period of inactivity before a DAQ module is allowed to begin its own transmission. Multiple Access (MA) means that once the bus is free, every DAQ module in the network has an equal opportunity to transmit a frame. And Collision Detection (CD) uses non destructive bit wise arbitration to preserve the integrity of a data frame when two or more DAQ modules try to transmit at the exact same time. And since the data frame that wins arbitration remains intact during a collision, there is no additional communications delay when a collision occurs no matter how often it happens.

Host Communications

To communicate with the DAQ modules, commands are sent to the individual units by including a header character at the beginning (the address) so that it can be routed to the appropriate unit. If using multiple units connected together, the DIP switch for each unit should be set to a different position so that it will be assigned a different header character. Each DAQ module has its own command set used to configure it, operate the functions, and to read data from it. These commands are listed in the product data sheets. A typical command string looks like this:

HCNV{cr}

H = Header Character
C = Command Character
N = Channel Number (if applicable)
V = Value (if applicable)
{cr} = Carriage Return

If using our ModCom HMI software, the carriage return is not necessary because ModCom automatically inserts this at the end of each command string. ModCom has a communications dialog box which can be used to transmit individual commands to the DAQ modules and see the data coming back. This is helpful in learning the style of the command-set protocol and testing the hardware that's attached to the DAQ module. It is highly recommended that this testing be done prior to setting up any complex control programs.